Home > Construction Admixture > SINOSI The world of silica & silicon

SINOSI The world of silica & silicon

Author: Justin

May. 27, 2024

55 0

SINOSI The world of silica & silicon

&#;&#;&#;&#;&#;

Are you interested in learning more about 90% Undensified Silica Fume? Contact us today to secure an expert consultation!


Product Re-order No.:


Research and Development

SINOSI R&D team and operation
SINOSI has a team of professional specialists and experts in geology, mineral, metallurgy, chemistry, machinery, electron, solar energy and international trading in the silica and silicon producing and trading business field in the world wide who have more than 10 to 20 years experiences for the research, testing, producing, quality controlling, business holding and team managing in the world wide market. Their profound theory and successful practical operation experience has been unanimously recognized and highly regarded in the field.

SINOSI technicians have actively combined traditional exploration, mining, processing techniques and modern smelting, purifying, analysis and controlling techniques and mechanics together. Through the study of geological theory of SiO2, Silicon molecule dynamics theory, granularity crystal plasticity deformation theory, molecule fission theory, inner crystal air-raid impurity deformation theory and other theories, handling the core sample to purifying refine process by mathematical models, Online QCS testing and controlling of materials and finished products with instruments of millionth to billionth precision, to ensure SINOSI to be the constant and steady provider of high-purity and super granularity silica and silicon materials to customers all over the world.

SINOSI silica and silicon resources
Our silica mines including quartz and crystal cover the provinces of Hebei, Jiangsu, Sichuan, Tibet, Gansu, Shanxi, Anhui, and Jiangxi provinces in China. At the mean time, we also choose some mine sites in India and Vietnam, Kazakhstan, Russia, Brazil and U.S. etc. The contain of the silica mine sites for which we have and share mining licenses is more than 5 billion metric tons and about 810 million metric tons of them can reach to the grade of crystal.

The silicon materials for the chemical industry, coating and filling industry, optic and glass industry, IC and PV industry coving around China and spread to the world wide market. Meanwhile, some of this silicon materials from oversea such as Japan, US, Germany, Korea etc. are also well serviced for China customers depending on SINOSI&#;s trading and related service accordingly.

SINOSI R&D responsibility
SINOSI has expertise and experience of successful producing and merchandising silica and silicon materials for many years. We have well-established business cooperation with domestic and international silica and silicon material users. While we are fully aware of the technology and marketing of world&#;s silica and silicon material industry, we realized that the quality of silica and silicon materials, especially the chemical components and physical properties such as purity, particle size, resistance and so on in order to bring Sinosi&#;s silica and silicon materials become the first-class materials in the world wide market and performance for any of the further producing and trading.

SINOSI R&D method and testing
SINOSI is supported by domestic and international technical institution, such as former Ministry of Geology & Mineral Resources of China, Ministry of Chemical Industry, Chinese Academy of Geological Sciences, Chemical Industry Research Institute, Physical and Chemical Analysis Institution of MGMRC, National Silica glass Center for Physical and Chemical Analysis and other scientific research institutions. Using the advanced experiences of mining, crushing, grinding, classification, dewatering, thermal processing and calcination, purifying, smelting as well as QCS controlling of the finished products with instruments of millionth to billionth precision, we may keep to produce and supply the high-purity, super-fined, spherical-powder silica and silicon materials to the world wide market.

SINOSI R&D instruments and performance
SINOSI utilizes highly restricted testing and analyzing instrument in the lab. and producing line in order to provide a performance for the processing and final result . Below listed are several generally adapted instruments:

1. Inductively Coupled Plasma Mass Spectrometry (ICP-MS)
2. Inductively Coupled Plasma Atomic Emission Spectrometry;(ICP-AES)
3. Neutron Activation Analysis (NAA)
4. Atomic Absorption Spectrometry (AAS)
5. Atomic Fluorescence Spectrometry (AFS)
6. Moleccular Spectroscopy (MS)
7. X-Ray Fluorescence Spectrometry (XRF)
8. Ion Chromatography (IC)
9. Polarography, Ion Selective Electrodes and Other Electro-Chemical Analysis Techniques.

All procedure shall be tested and filed as per SINOSI internal regulations, and all products must be inspected before leaving the factory or warehouse to ensure the product quality.

SINOSI R&D Achievements
We are currently researching and developing some of new silica and silicon materials  and related products, and the key items are as follow:

1. Nano Meter Silica Powder
We have achieved a new type of 20 to 500 nano meter silica power with a 99.9% SiO2 purity in the laboratory and also successed in the producing line. The BET surface has been reached to 20 square meters per gram (20M2/g), and keep an amorphous and hydrophilic type by a particle size.

2. Spherical Fused Silica Micro Powder
Our spherical fused silica micro powder (SSP Series) has been reached to SiO2 purity 99.99% min, spherical ratio 98%, and particle size 0.15u in the laboratory and SiO2 purity 99.9% min. spherical ratio 95% min. and particle size 0.5 to 15u with a good D50 size distribution in our producing line.

3. High Purity Quartz Sand
Our high purity quartz sand (HPQ Series) now has been achieved the SiO2 purity 6N (99.%) in the laboratory and 4 to 5N (99.99 to 99.999%) on the production line. This materials are widely used for the crucible, tube, rod and plate/disc and so on for PV and lighting industries.

4. Solar grade mono and polycrystalline silicon
We have achieved the new technique for producing and purifying of the silicon materials which is using for the PV industry in the solar energy field. The focus of this new technique is using the modern smelting, chemical processing and purifying instead of the traditional Siemen&#;s way which will be down more the producing cost and still reach to Si purity 6N (99.%) min. and electric resistance 0.5ohm/cm min.

5. Silicon Carbon Coating Material
As a cooperate partner with Optimum Polymer Technologies (USA), we now are authorized as the exclusive distributor in China market for providing the silicon carbon coating material in China market which can be widely used for painting, lens, glass, hub and so on in the car care business field and PV glass industry.  

You are always welcome in our SINOSI team
We, SINOSI welcome all exports and specialists in this field to join our SINOSI R&D team. If you feel any interesting, please kindly contact our Human Resources Dept. by:
:  or

 

Specifications for Reduced pH Reef Ball Concrete

Searches all Reef Ball related web sites.

 

The Reef Ball Foundation, working closely with concrete experts, has developed a typical mix design suitable to create artificial reef modules in complex molds with a minimal pH and to enhance the settlement and growth of typical marine species such as hard corals. Specific biological goals, such as oyster settlement, may require specialized designs. If you can not find local materials to match these specifications because of admixture or cement type availability, there are several acceptable substitutions, contact us for information. In general, this starting mix design has the highest amount of Portland Cement to help insure that you don't break your Reef Balls when handling them. However, Reef Ball usually don't need this much Portland cement when handled carefully, and there are additional biological benefits of using less cement because this can further reduce concrete pH. If you are reaching your goal of 95% or better of your modules not being broken you might consider reducing your cement proportions. Remember that best concrete practices are required for good pH neutralization; primarily the use of fresh cement, complete mixing, and good curing conditions (high humidity for at least 30 days)....without good practices all the microsilica in the world won't prevent a high pH.

Contact us if you have any questions about your mix design, to obtain approval for deviations or if you need a custom design for a specific project.

PART I - GENERAL

1.01 Section Includes

A. Concrete proportioning and products to be used to secure concrete, which when hardened will produce a required strength, permeability, and resistance to weathering in a reef environment.

1.04 References

A. ACI-211.191-Standard Practice for Selecting Proportions for Normal, Heavyweight, and Mass Concrete.
B. ASTM C 260- Standard Specifications for Air-Entraining Admixtures for Concrete.
C. ASTM-C Type III- Standard Specifications for Fiber Reinforced Concrete or Shotcrete.
D. ACI - 305R -91- Hot Weather Concreting.
E. ACI - 306R -88- Cold Weather Concreting.
F. ACI - 308- Standard Practice for Curing Concrete.
G. ASTM C 618-Fly Ash For Use As A Mineral Admixture in Portland Cement Concrete.
H. ASTM C 494-92- Standard Specifications for Chemical Admixtures for Concrete.
I. ASTM C -91- Electrical Indication of Concrete's Ability to Resist Chloride Ion Penetration.
J. ASTM C 33- Concrete Aggregates.
K. ASTM C 94- Ready Mix Concrete.
L. ASTM C 150-Portland Cement.
M. ACI 304- Recommended Practice For Measuring, Mixing, Transporting and Placing concrete.
N. ASTM C 39 (Standard Specifications For Compressive Testing)
O. ASTM C--93 (Standard Specifications for Silica Fume Concrete)

PART II PRODUCTS

2.01 Portland Cement: Shall be Type II and conform to ASTM C-150

2.02 Fly Ash: Shall meet requirements of ASTM C-618, Type F. And must be proven to be non-toxic as defined by the Army Corps of Engineers General Artificial Reef Permits. Fly Ash is not permitted in the State of Georgia and in most Atlantic States. (In October, , The Atlantic States Marine Fisheries Commission adopted a resolution that opposes the use of fly ash in artificial reefs other than for experimental applications until the Army Corps of Engineers develop and adopt guidelines and standards for use.)

2.03 Water: Shall be potable and free from deleterious substances and shall not contain more that parts per million of chlorides or sulfates and shall not contain more than 5 parts per million of lead, copper or zinc salts and shall not contain more than 10 parts per million of phosphates.

2.04 Fine Aggregate: Shall be in compliance with ASTM C-33.

2.05 Coarse Aggregate: Shall be in compliance with ASTM C-33 #8 (pea gravel). (Up to 1 inch aggregate can be substituted with permission from the mold user.) Limestone aggregate is preferred if the finished modules are to be used in tropical waters.

2.06 Concrete Admixtures: Shall be in compliance with ASTM C-494.

2.07 Required Additives: The following additives shall be used in all concrete mix designs when producing the Reef Ball Development Group's product line:

A. High Range Water Reducer: Shall be ADVA Flow 120 or 140.

B. Silica Fume: Shall be Force 10,000 Densified in Concrete Ready Bags as manf. by W.R. Grace. (ASTM C--93) or any of the permitted equivalent silica fume Brands as defined in the training manual Appendix K

C. Air-Entrainer: ONLY IF ADVA is not used: Shall be Darex II as manf. by W.R. Grace (ASTM C-260)

2.08 Optional Additives: The following additives may be used in concrete mix designs when producing Reef Ball Development's product line.

A. Fibers. Shall be either Microfibers as manf. by W.R. Grace, or Fibermesh Fibers (1 1/2 inches or longer) as manf. by Fibermesh. Either November 1, ators:  Any Non- Calcium Chloride or Daracell as manf. by W.R. Grace may be used. (ASTM C-494 Type C or E)

C. Retarders: Shall be in compliance with ASTM-C-494-Type D as in Daratard 17 manf. by W.R. Grace

2.09 Prohibited Admixtures: All other admixtures are prohibited. Other admixtures can be submitted for approval by the Reef Ball Foundation Inc. Services Division by sending enough sample to produce five yards of concrete, the current MSDS, and chemical composition (which will be kept confidential by RBDG Ltd.) A testing fee of $2,500 must accompany the sample. Temporary approval will be granted or denied within 10 days based on chemical composition, but final approval may take up to 3 months since samples must be introduced in a controlled aquarium environment to assess impacts on marine and freshwater species.

PART III Concrete Proportioning:

A. General: The intent of the following proportions is to secure concrete of homogeneous structure which will have required strength and resistance to weathering.

B. Proportions:

 

One Cubic Yard

One Cubic Meter

Cement:

600 lbs. (Min.)

356 kg

Aggregate:

lbs.

kg

Sand:

lbs

688 kg

Water:

240 1bs. (Max.)

142 kg

Force 10K:

50 lbs

30 kg

Grace Microfibers

.25 bag

.3 bag

*Adva Flow 120 or

Adva Flow 140

3.5-5 ounces per 100 lbs cement
or
6-10 ounces per 100 lbs cement

1

*NOTE: Adjust Adva dosage as needed to obtain workable, placeable mix (170-250mm / 7-10 inch slump), and to achieve .40 w/c ratio.

Fibers: 0-3# (Max.) as needed to reduce micro cracking 1# (Min.) required if Silica Fume exceeds 50#

Accelerator: As needed to achieve de-molding no sooner than: 3-4 hours for heavy duty molds (All Polyform side balls) 6-7 hours for standard molds (Molds with any tether balls)

 

NOTE: Silica Fume or Force 10K shall be dosed at a 10# minimum in Bay Balls and Pallet Balls while Ultra & Reef Balls shall require a minimum of 25#. All molds must use at least 50# for floating deployments. All mold sizes must use at least 50# for use in tropical waters unless special curing procedures are followed.* This product is being specified not only for strength, but also to reduce pH to spur coral growth, to reduce calcium hydroxide, and to increase sulfate resistance. It is a non-toxic pozzalan.

* Special curing procedures for tropical waters without 50# of Silica Fume per yard should include storage in a fresh water or high humidity environment  for a minimum of 60 days or less with higher temperatures, or until the surface pH of the modules is below 9.5 pH when placed in seawater.

NOTE: End of day concrete may be used, but follow these additional requirements.

-Do not use concrete that has a temperature of over 100 degrees Fahrenheit -The original mix must have been at least 3,500 PSI -50# of added microsilica or more is required unless microsilica at that dose was already in the starting mix -Add additional Portland if needed to achieve a .4 w/c ratio. Take into account water added on site -Advise mold user to allow extra time for curing to achieve minimum de-molding strength. -Mold or module user must be notified that EOD waste was used.

NOTE: Fly Ash, when permitted, may be used as a substitution for cement up to a maximum replacement of 15% and as an additional substitute for microsilica at 30% to 40% of cementitious material. (Call RBDG for details.)

Part IV Concrete Testing Requirements:

A. Compressive strengths shall be tested in accordance with ASTM C 39. Compressive strengths shall reach a minimum of the following table at the time of use of at least:

 

 

Super/Ultra/Reef Ball

Pallet Ball

Bay Ball and all smaller sizes

Floating Deployment

8,500+

7,000+

6,000+

Barge Deployment

7,000+

Contact us to discuss your requirements of 85% Densified Silica Fume. Our experienced sales team can help you identify the options that best suit your needs.

Related articles:
What Does Praziquantel Treat in Animals?
5 Uses of Benzocaine
What is hydroxypropyl methyl cellulose used for?
What is the difference between Ivomec and Ivermectin?
what is cas 1121-84-2 2h pyran 2 one tetrahydro 4 methyl
The Versatility of 30% Salicylic Acid: Applications and Benefits
Ethyl Acetate Production Plant: Unveiling the Process from Start to Finish

5,500+

4,000+

To remove from mold

750+

750+

750+

To lift from base

1,500+

1,200+

1,000+

B. Permeability of concrete shall be tested in accordance with ASTM C -91. Coulomb requirement shall be coulombs or less at 90 days. End of day waste shall be coulombs or less at 90 days.

THIS SPECIFICATION SHEET IS ONLY A SAMPLE. CONTACT RBDG FOR CUSTOM SPECIFICATIONS.

1) All deployments made by authorized contractors must have at least 90% of modules upright and intact or they must supply free deployed replacement to purchaser. This is REGARDLESS of what the customer says is acceptable.

2) All new construction after Jan. 1, must use ADVA Flow superplastisizer rather than WRD-19, Reduce the amount of air entrainment by 35-50% so that entrainment remains at 6% +/- 2%. (This will not impact your costs).

2a) All new construction after July must have Attachment Adapter Plug system installed and at least 50% of the recommended number of attachment adapters for the particular sized Reef Ball must be usable.

3) All Reef Balls must be constructed with a "wavy" bottom formed by adding sand in the mold before inserting center bladder.

4) The rinsing of the outside layer of concrete is not optional to expose the surface texture due to the pH rise on the surface of the poorly set concrete. (If rinsing is impractical, use a non-oil based biodegradable mold-releasing compound instead of sugar water. Increase air entrainment to 8% and do not tap the concrete into the mold heavily to create as much "honeycombing" as you can.)

5) The following are MINIMUM guidelines for microsilica use, primarily for pH reduction. Again, these are REGARDLESS of what the customer says is acceptable.

Hard Corralled Waters (Florida border & south on East Coast, Hernando County and south on Gulf.) (Anywhere near the Flower Gardens of Texas, anywhere near Grey's Reef in SC)

Deployed less than 45 days from casting = 50 lbs/yard
Deployed > 45 days < 90 days from casting = 45 lbs/yard
Deployed > 91 days < 120 days from casting = 40 lbs/yard
Deployed > 121 days < 150 days from casting = 35 lbs/yard
Deployed > 151 days < 180 days from casting = 30 lbs/yard
Deployed > 181 days < 210 days from casting = 25 lbs/yard
Deployed > 211 days < 240 days from casting = 20 lbs/yard
Deployed > 240 from casting = 15 lbs/yard

Temperate / Cool Waters (North of above & all of West Coast)

Deployed less than 29 days from casting = 50 lbs/yard
Deployed > 30 days < 90 days from casting = 30 lbs/yard
Deployed > 91 days < 120 days from casting = 25 lbs/yard
Deployed > 121 days < 150 days from casting = 20 lbs/yard
Deployed > 151 days < 180 days from casting = 15 lbs/yard
Deployed > 181 days < 210 days from casting = 10 lbs/yard
Deployed > 211 days < 240 days from casting = 5 lbs/yard
Deployed > 240 from casting = not required

6) End of day waste still requires full 50 lbs/yard of Mircosilica regardless of location/time

7) All other proprietary standards, including an approved mix design must be upheld.

 

 

FIbermess Product Guide Specifications

SI Concrete Systems                     
Industry Drive
Chattanooga, Tennessee  
Toll Free                      (800) 621-
                      (423) 892-
Fax                      (423) 892-
Website                      www.siconcretesystems.com
                     

Specifier Notes:  This product guide specification is written according to the Construction Specifications Institute (CSI) 3-Part Format as described in The Project Resource Manual&#;CSI Manual of Practice.  The section must be carefully reviewed and edited by the Architect or Engineer to meet the requirements of the project and local building code.  Coordinate this section with other specification sections and the Drawings.  Delete all &#;Specifier Notes&#; when editing this section.

Section numbers are from MasterFormat Edition, with numbers from MasterFormat Edition in parentheses.  Delete version not required.

 

SECTION (03 24 00)

SYNTHETIC FIBER REINFORCEMENT

 

Specifier Notes:  This section covers SI Concrete Systems Fibermesh® 150 polypropylene fibers for use as concrete secondary reinforcement.  Consult SI Concrete Systems for assistance in editing this section for the specific application.

 

PART 1                     GENERAL

1.1            SECTION INCLUDES

A.            Polypropylene fibers used as concrete secondary reinforcement.

1.2            RELATED SECTIONS

Specifier Notes:  Edit the following list of related sections as required for the project.  List other sections with work directly related to this section.

A.      Section (32 13 00) - Rigid Paving.

B.     Section (03 21 00) - Reinforcing Steel.

C.     Section (03 30 00) - Cast-in-Place Concrete.

D.     Section (03 37 13) - Shotcrete.

E.     Section (03 50 00) - Cementitious Decks and Toppings.

1.3            REFERENCES

Specifier Notes:  List standards referenced in this section, complete with designations and titles.  This article does not require compliance with standards, but is merely a listing of those used.

A.      ASTM C 94 - Standard Specification for Ready-Mixed Concrete.

B.     ASTM C - Standard Specification for Fiber-Reinforced Concrete and Shotcrete.

C.            Southwest Certification Services (SWCS), Omega Point Laboratories No. -1.

D.     UL Report File No. R-11.

1.4            SUBMITTALS

A.      Comply with Section (01 33 00) - Submittal Procedures.

B.            Product Data:  Submit manufacturer&#;s product data, including application rate and mixing instructions.

Specifier Notes:  Delete samples if not required.

C.            Samples:  Submit manufacturer&#;s sample of synthetic fiber reinforcement.

D.            Manufacturer&#;s Certification:
1.   Submit manufacturer&#;s certification that synthetic fiber reinforcement complies with specified requirements.
2.   Submit evidence of manufacturer&#;s ISO : certification.
3.   Submit evidence of satisfactory performance history of synthetic fiber reinforcement.

1.5            QUALITY ASSURANCE

A.            Manufacturer&#;s Qualifications:
1.   Synthetic fiber reinforcement manufactured in ISO : certified facility.
2.   Minimum 10-year satisfactory performance history of specified synthetic fiber reinforcement.

1.6            DELIVERY, STORAGE, AND HANDLING

A.            Delivery:  Deliver synthetic fiber reinforcement in manufacturer&#;s original, unopened, undamaged containers and packaging, with labels clearly identifying product name, unique identification number, code approvals, directions for use, manufacturer, and weight of fibers.

B.            Storage:
1.   Store synthetic fiber reinforcement in clean, dry area indoors in accordance with manufacturer&#;s instructions.
2.   Keep packaging sealed until ready for use.

C.            Handling:  Protect synthetic fiber reinforcement during handling to prevent contamination.

 

PART 2                     PRODUCTS

2.1            MANUFACTURER

A.      SI Concrete Systems, Industry Drive, Chattanooga, Tennessee .  Toll Free (800) 621-.  (423) 892-.  Fax (423) 892-.  Website www.siconcretesystems.com.  .

2.2            SYNTHETIC FIBER REINFORCEMENT

A.            Synthetic Fiber Reinforcement:  Fibermesh 150.
1.   Material:  100 percent virgin homopolymer polypropylene multifilament fibers, containing no reprocessed olefin materials.
2.   Conformance:  ASTM C , Type III.
3.   Fire Classifications:
a.      UL Report File No. R-11.
b.      Southwest Certification Services (SWCS), Omega Point Laboratories No. -1.

Specifier Notes:  Specify graded or single-cut lengths.

4.   Fiber Length:  [Graded]  [Single-cut lengths].
5.   Alkali Resistance:  Alkali proof.
6.   Absorption:  Nil.
7.   Specific Gravity:  0.91.
8.   Melt Point:  324 degrees F (162 degrees C).

 

PART 3                     EXECUTION

3.1            MIXING

A.      Add synthetic fiber reinforcement to concrete mixture in accordance with manufacturer&#;s instructions.

B.     Add synthetic fiber reinforcement into concrete mixer before, during, or after batching other concrete materials.

Specifier Notes:  Lower application rates may be acceptable depending upon local building codes.  Consult SI Concrete Systems for more information.

C.            Application Rate:  Add synthetic fiber reinforcement at standard application rate of 1.5 pounds per cubic yard (0.90 kg/m3) of concrete.

D.     Mix synthetic fiber reinforcement in concrete mixer in accordance with mixing time and speed of ASTM C 94 to ensure uniform distribution and random orientation of fibers throughout concrete.

Force 10,000 Specifications (Microsilica)

Concrete Products
Technical Guide Specification
Microsilica Concrete
SECTION
PART 1 - GENERAL
1.01               SUMMARY
A.    This section specifies microsilica (silica fume) admixture for the reduction of concrete permeability to protect against intrusion by chlorides and other aggressive chemicals, and for the production of high-strength concrete.
B.        Related Sections: Other specification sections which directly relate to the work of this Section include, but are not limited to, the following:
1.               Section - Cast-In-Place Concrete.
2.               Section - Post-Tensioned Concrete.
3.               Section - Precast Concrete.
1.02               SUBMITTALS
A.        Product Data: Submit manufacturer&#;s product data, installation instructions, use limitations and recommendations for each material.
B.    Test and Performance Data: Submit independent test data substantiating the product&#;s ability to reduce concrete permeability by chlorides and other aggressive chemicals.
1.03               QUALITY ASSURANCE
A.        Manufacturer: Concrete admixture shall be manufactured by a firm with a minimum of 5 years experience in the production of similar products. Manufacturers proposed for use but not named in these specifications shall submit evidence of ability to meet all requirements specified, and include a list of projects of similar design and complexity completed within the past five years.
B.        Materials: For each type of material required for the work of this Section, provide primary materials which are the products of one manufacturer.
C.    Pre-Construction Conference: A pre-construction conference shall be held two weeks prior to commencement of field operations to install the specified product in order to establish procedures to maintain optimum working conditions and to coordinate this work with related and adjacent work. Agenda for meeting shall include concrete and admixture handling, placing, finishing, and curing.
D.        Manufacturer&#;s Representative: A representative of the manufacturer shall be present for project start-up during initial concrete placement. Engineer may waive requirement for manufacturer&#;s representative if Contractor provides sufficient evidence that producer and finisher have adequate experience with admixtures required.
E.        Trial Mix: Provide a minimum 4 cubic yard (3 m3) trial mix containing proposed concrete design mix placed at the job site in location acceptable to the Engineer. Engineer may waive requirement for trial mix if Contractor provides sufficient evidence that producer and finisher have adequate experience with low water cement ratio mixes.
1.04               PROJECT CONDITIONS
A.        Perform work only when existing and forecasted weather conditions are within the limits established by the manufacturer of the materials and products used.
PART 2 - PRODUCTS
2.01               MANUFACTURER      
A.        Provide Force 10,000® microsilica concrete admixtures by Grace Construction Products meeting specified requirements. For customer service in North America:
Call toll free:                              877-4AD-MIX1               (877-423-)
Fax toll free:                              877-4AD-MIX2               (877-423-)
2.02               MATERIALS     
A.        Microsilica Admixture: Provide Force 10,000 concrete admixture by Grace Construction Products complying with ASTM C .
2.03               CONCRETE MIXES    
A.        Application Rate:
NTS  This section may be used for concrete permeability requirements or high-strength concrete.  Application rate (dosage rate) of microsilica may vary depending on individual project requirements.  Application rates may be stated in dry pounds per cubic yard, percent of weight of cement, or as required to meet a performance criteria. Typical application rates for low permeability concrete varies from 30 to 60 lbs/cy. Specifier should use only one of the three sections which follow for A. Application Rate.

NTS  Force 10,000 Sample Specification For Permeability Requirements
This sample specification may be used by the design engineer when specifying Force 10,000 microsilica for the reduction of concrete permeability to protect against intrusion by chlorides or other aggressive chemicals. Force 10,000 is a microsilica-based admixture manufactured by Grace Construction Products of W. R. Grace & Co.-Conn.
The high silicon dioxide content of microsilica combines with the excess calcium hydroxide in the concrete to form more calcium silicate hydrate &#;glue.&#; This chemical reaction plus its fine particle size allows Force 10,000 to fill in the voids between the cement grains and aggregate to deliver less permeable concrete. When chlorides migrate through the concrete and attack the steel reinforcing, corrosion occurs.  By reducing the permeability of the concrete, chlorides take much longer to reach the steel which extends the service life of the structure considerably. Chlorides are typically present from deicing salts or from a marine environment. Structure applications of Force 10,000 include parking garages, bridge decks and overlays, reinforced pavements, and all structures in a marine environment. Structural concrete design criteria shall follow ACI 318, 357 and 201 guidelines. Parameters used in this sample specification, such as water/cementitious ratio and concrete cover over reinforcing steel, are taken from these guidelines and are conservative values.
There are two ways to specify microsilica concrete for permeability requirements: by prescription or by performance. The prescription method mandates the number of pounds of microsilica per cubic yard to be used while the performance method uses ASTM C test method to measure &#;coulombs.&#; Please use one method (prescription or performance) but not both.  If the &#;performance method&#; is the preferred choice, use ASTM C for mix design purposes only, not as a mix acceptance or rejection criteria during the construction phase. Since the chloride&#;s loading rate and final concrete quality are unknown factors, W. R. Grace cannot guarantee the longevity of the protection offered by Force 10,000. Quality concrete as recommended by ACI and the addition of Force 10,000 will slow the ingress of chlorides into the concrete. Neither quality concrete nor Force 10,000 will stop corrosion forever, but both will retard the onset of corrosion.
Prescription Method
1.               Provide microsilica admixture Force 10,000 as manufactured by Grace Construction Products.
2.               Microsilica shall be added at a rate of (50) pounds dry weight of microsilica per cubic yard [(30) kg/m3] of concrete.
3.               Compressive strength shall be a minimum of (5,000) psi [35 MPa] at 28 days as measured using (4&#; x 8&#;) (100 mm x 200 mm) cylinder specimens.
4.               A maximum water-to-cementitious ratio of 0.40 is required.
5.               Microsilica may be counted as cementitious material in calculations.
6.               Add microsilica as a liquid slurry or in dry densified form in 25 lb (11.4 kg) Concrete Ready BagsTM packaging.
7.               Blended cements with interground microsilica will not be allowed.
Performance Method
1.               Provide microsilica admixture Force 10,000 as manufactured by Grace Construction Products.
2.               Microsilica shall have a minimum of (5,000) psi [35 MPa] at 28 days as measured using (4&#; x 8&#;) (100 mm x 200 mm) cylinders.
3.               Permeability of microsilica concrete shall be tested by ASTM C .  Results of tests shall be expressed in electrical units of coulombs. Coulomb tests shall be made on two (4&#; x 8&#;) (100 mm x 200 mm) representative samples, moist cured for 56 days.  Test cylinders shall be made according to ASTM C 31. Coulomb requirement shall be (_____) coulombs or less at 56 days.  ASTM C testing shall be used as an indicator of concrete permeability at mix design submittal only.
4.               A maximum water-to-cementitious ratio of 0.40 is required. 
5.               Microsilica may be counted as cementitious material in calculations.
6.               Add microsilica as a liquid slurry or in dry densified form in 25 lb (11.4 kg) Concrete Ready Bags packaging.
7.               Blended cements with interground microsilica will not be allowed.
NTS:      Force 10,000 Sample Specification For High-Strength Concrete Requirements
               This sample specification may be used by the design engineer when specifying Force 10,000 microsilica for the production of high-strength concrete. The design engineer should fill in the compressive strength required. Force 10,000 is a microsilica-based admixture manufactured by Grace Construction Products of W. R. Grace & Co.-Conn. The high silicon dioxide content of microsilica combines with the excess calcium hydroxide in the concrete to form more calcium silicate hydrate &#;glue.&#; This produces a stronger, tighter bonding paste structure. Additionally, the extreme fineness of the microsilica enables it a less permeable paste. These two factors contribute to providing higher strength, more durable concrete.
               Structural applications for high strength Force 10,000 concrete are broad, but include usage in structural columns, beams and girders. Structural concrete design criteria shall follow ACI 318, 357 and 201 guidelines. Parameters used in this sample specification, such as water-to-cementitious ratio are taken from these guidelines and are conservative values. This sample specification is based on the performance method, whereby the compressive strength of the concrete is mandated by the design engineer.
High-Strength Concrete Requirements
1.               Provide microsilica admixture Force 10,000 as manufactured by Grace Construction Products.
2.               Microsilica high-strength concrete shall have a minimum of (____) psi [(___) MPa] at 28 days.
3.               Test cylinders shall be 4&#; x 8&#; (100 mm x 200 mm).
4.               A maximum water-to-cementitious ratio of 0.40 is required.
5.               Microsilica may be counted as cementitious material in calculations.
6.               Add microsilica as a liquid slurry or in dry densified form in 25 lb. (11.4 kg) Concrete Ready Bags packaging.
7.               Blended cements with interground microsilica will not be allowed.
B.        Concrete Cover Over Reinforcement:  Minimum concrete cover over reinforcement shall be (____) inches [(____) mm].
NTS:  Follow ACI 318 recommendations for concrete cover over reinforcement.  For deicing salt and marine environments, ACI 318-89, section R7.7.5, requires 2 inches (50 mm) for walls and slabs and 2-1/2 inches (64 mm) for other members. For marine environments, ACI 357 recommends 2-1/2 inches (64 mm).
C.    Air Entrainment: For freeze-thaw durability comply with ACI 318 freezing and thawing exposure requirements, as determined by ASTM C 173 or ASTM C 281.
D.        Water-to-Cementitious Ratio: Provide 0.40 maximum. Microsilica, fly ash, blast furnace slag and cement are considered cementitious materials. The water content of Force 10,000 slurry shall be included as mix design water.
E.        Recommended Cementitious Content for Workability:
                       Maximum Aggregate      Minimum Cementitious                           
                            3/8&#;                            (10 mm)                            700 pounds/cu.yd.  (415 kg/m3)      
                            1/2&#;                            (13 mm)                            680 pounds/cu.yd.  (400 kg/m3)      
                            3/4&#;                            (20 mm)                            650 pounds/cu.yd.  (385 kg/m3)      
                            1&#;                            (25 mm)                            630 pounds/cu.yd.  (375 kg/m3)      
F.        Compressive Strength: Minimum 28 day compressive strength for microsilica concrete shall be (5,000) psi [(35) MPa] unless stated otherwise in Section 2.03 A. Application Rate.
G.        Concrete Slump for Flatwork: 5 to 8 inches (125 to 200 mm). Concrete slump may be 2 inches (50 mm) over normal concrete slumps as microsilica concrete can be sticky and has a surface that is harder to close than normal concrete. 
H.        Concrete Admixtures: High-range water reducers are mandatory to control slump, mixing, cementitious ratio and proper distribution of the microsilica, and shall be plant added. Additional water reducers may be added at the job site when required.
I.        Additional Concrete Admixtures: Additional concrete admixtures conforming to ASTM C 494 or equivalent CSA 266 standards may be used as required including the following:
1.               Type A: Water-reducing admixture, WRDA® series or Daracem®-55 by Grace Construction Products.
2.               Type D: Water-reducing and retarding admixture, Daratard®-17 by Grace Construction Products.
3.               Type F or G: Water-reducing, high-range admixture, WRDA-19, Daracem-100 by Grace Construction Products. This type of admixture must be included in all Force 10,000 concrete.
4.               Type C: Accelerating admixture, PolarSet® by Grace Construction Products.
5.               Grace MicroFibers® for flatwork, at 1 pound per cubic yard (600 grams/m3) addition rate.
6.               DCI® or DCI-S Corrosion Inhibitor by Grace Construction Products may also be used if required at rate recommended by manufacturer.
J.        Special Mixing Requirements for Densified Microsilica: Densified microsilica requires enhanced mixing to ensure full dispersion.  The following mix requirements shall be adhered to:
1.               For all types of mixing equipment, mix times shall be increased by 40% over the minimum mix time required to achieve mix uniformity as defined by ASTM C 94.
2.               For truck-mixed and central mixed concrete, maximum allowable batch size shall be 80% of the maximum as called out by ASTM C 94.
PART 3 - EXECUTION
3.01               EXAMINATION
A.        Examine conditions of substrates and other conditions under which work is to be performed and notify Owner, in writing, of circumstances detrimental to the proper completion of the work. Do not proceed until unsatisfactory conditions are corrected.
3.02               CONCRETE PLACEMENT, FINISHING AND CURING
A.        Concrete Finishing and Curing: Microsilica concrete typically exhibits little or no bleeding. To reduce plastic or drying shrinkage cracks, comply with ACI 302 &#;Guide for Concrete Floor and Slab Construction&#;, ACI 308 &#;Standard Practice for Curing Concrete&#;, ACI 306 &#;Standard Practice for Cold Weather Concreting&#;, and ACI 305 &#;Hot Weather Concreting.&#;
1.               Underfinish microsilica concrete by limiting finishing operation to screeding, bull-float, and broom finish. Curing shall be initiated within one hour of concrete placement.
2.               The use of wind breaks, sun shades, and fog misting are recommended to minimize the rate of evaporation at the concrete surface.
3.               Light fog misting above the concrete to keep the environment above the concrete surface at high humidity is recommended during the placing and finish operations.


4.               Fog misting is required when the rate of evaporation at the concrete surface exceeds 0.1 pound per square foot per hour as determined by ACI 308 Section 1.2.1. Fogging shall continue after the finishing operation until prewetted burlap or other approved curing material is placed over the concrete. When fog misting is not available or possible, an evaporation retarder shall be applied before and after bull-floating and during final finish to protect the concrete.
5.               Wet curing is the preferred method for curing. Use prewetted burlap to cover all flatwork and keep wet for a minimum of seven days or until the time necessary to attain 70 percent of the specified compressive strength, as recommended by ACI 308 Section 3.1.3.
3.03               PROTECTION
A.        Protect completed work from damage and construction operations throughout finishing and curing operations.

 

 

 

 

For more 94% Densified Silica Fumeinformation, please contact us. We will provide professional answers.


Related articles:
What is a pharmaceutical intermediate?
Application of SBR Latex for Artificial Turf
What is the use of zinc sulfate in agriculture?
Exploring the Versatile Properties of Hydroxyethyl Cellulose
Acetylene Industrial Gas: Revolutionizing Manufacturing Processes
What is the best solvent for silicone oil?
Discover the Top Benefits of Osi Oils for Improved Health and Wellness

Comments

0